| Customization: | Available |
|---|---|
| After-sales Service: | Provided |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Item | Unit | Parameter | |
| Pumping system | Max. theoretical delivery volume | m³/h | 50 |
| Max. theoretical delivery pressure | MPa | 13 | |
| Max. theoretical delivery height (Φ125) | m | 150 | |
| Max. theoretical delivery distance (Φ125) | m | 350 | |
| Max. delivery frequency (Low/High pressure) | times/min | 23 | |
| Distribution valve type | S tube valve | ||
| Main oil cylinder specification: cylinder dia./role dia. × stroke | mm | 125/80×1200 | |
| Concrete cylinder specification | mm | 200×1200 | |
| Hopper capacity | L | 500 | |
| Output opening diameter | mm | 150 | |
| Power system | Diesel engine power | KW | 75 |
| Rated rotation speed | r/min | 2200 | |
| Hydraulic system | Type of Hydraulic oil circuit | Open oil circuit | |
| Maximum oil pressure of pumping system | MPa | 28 | |
| Maximum oil pressure of mixing system | 14 | ||
| Highest mixing speed | r/min | 24 | |
| Hydraulic oil tank capacity | L | 300 | |
| Allowable max. dia.of aggregate | mm | 30 | |
| Inner dia.of concrete delivery pipe | mm | Φ125 | |
| Dimension(length× width× height) | mm | 5270×1860×2580 | |
| Weight | kg | 4000 | |